DC/DC Brick Power Converters

  • Extensive range of PCB mounting dc/dc converters
  • Power range from 1W to 60W
  • Input options cover the 5V, 12V, 24V and 48V range
  • Input range of 2:1 or wide range input 4:1


  • BR45D-65

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Mode)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • UL60950-1 and CSA C22.2 No. 60950-1-07
  • Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 2.28 x 1.45 x 0.38 Inches (BR65S-1.2S) 2.28 x 1.45 x 0.4 Inches (BR45D/BR65D)

    BR100

  • Input under Voltage Protection
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Mode)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • UL60950-1 and CSA C22.2 No. 60950-1-07
  • Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 1.3 x 0.9 x 0.5 Inches

    BR120

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Model)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • UL60950-1 and CSA C22.2 No. 60950-1-07
  • Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 2.28 x 1.45 x 0.39 Inches

    BR130

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Mode)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • UL60950-1 and CSA C22.2 No. 60950-1-07
  • Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 2.28 x 1.45 x 0.38 Inches (others Model) 2.28 x 1.45 x 0.39 Inches (BR130-3.3S) 2.28 x 1.45 x 0.5 Inches (BR130-3.3SB)

    BR240

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Mode)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Activates Hardware and Software
  • Digitally Adjusts the Voltage
  • PMBus Revision 1.1 compliant
  • Secondary ON/OFF Control Pre-Bias Function UL60950-1 and CSA C22.2 No. 60950-1-07 Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 2.3 x 0.9 x 0.5 Inches

    BR300

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Mode)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • UL60950-1 and CSA C22.2 No. 60950-1-07
  • Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 2.28 x 1.45 x 0.5 Inches

    BR360

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Mode)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • Negative Logic:BR360-3.3S and BR360-12S
  • Positive Logic:BR360-48S UL60950-1 and CSA C22.2 No. 60950-1-07 Meet UL94V-0 Flammability Requirements RoHS6 Compliant Size: 2.4 x 2.28 x 0.5 Inches

    BR400

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Mode)
  • Over Temperature Protection (Self-recovery)
  • Activates Hardware and Software
  • Digitally Adjusts the Voltage
  • PMBus Revision 1.1 compliant
  • Secondary ON/OFF Control
  • Pre-Bias Function Peak Efficiency:96%(12V,16.5A) UL60950-1 and CSA C22.2 No. 60950-1-07 Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 2.28 x 1.45 x 0.5 Inches

    BRH100

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Hiccup Mode)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • UL60950-1 and CSA C22.2 No. 60950-1-07
  • Meet UL94V-0 Flammability Requirements
  • Compliant Rohs6
  • Size: 2.28 x 1.45 x 0.38 Inches (BRH100-24S)
  • Size: 2.28 x 1.45 x 0.5 Inches (BRH100-96S/53.5S))
  • POL10

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Self-recovery)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • Monotonic Start-Up Into Pre-Biased Outputs
  • Meet UL94V-0 flammability requirements
  • Size: 2.0 x 0.5 x 0.33 Inches (POL16-05)
  • 2.0 x 0.55 x 0.47 Inches (others Model)
  • POL16

  • Input under Voltage Protection
  • Over Current Protection (Hiccup Mode)
  • Short Circuit Protection (Hiccup Mode)
  • Over Voltage Protection (Self-recovery)
  • Over Temperature Protection (Self-recovery)
  • Remote ON/OFF Control
  • Remote Sense
  • Output Voltage Trim
  • Monotonic Start-Up Into Pre-Biased Outputs
  • Meet UL94V-0 flammability requirements
  • Size: 2.0 x 0.5 x 0.33 Inches (POL16-05)
  • 2.0 x 0.55 x 0.47 Inches (others Model)